SC
Vendor
Schneider-electric
3,941
CVEs
1
On KEV
6
New 30D
Products
SR8.6
Sage RTU 1410
Schneider Electric
1 CVEs0 on KEV1 new
SR8.6
Sage RTU 1430
Schneider Electric
1 CVEs0 on KEV1 new
SR8.6
Sage RTU 1450
Schneider Electric
1 CVEs0 on KEV1 new
SR8.6
Sage RTU 2400
Schneider Electric
1 CVEs0 on KEV1 new
SR8.6
Sage RTU 3030 Magnum
Schneider Electric
1 CVEs0 on KEV1 new
SR8.6
Sage RTU 4400
Schneider Electric
1 CVEs0 on KEV1 new
UB9.8
U.motion Builder
Schneider Electric
24 CVEs1 on KEV0 new
SD9.8
Struxureware Data Center Expert
Schneider-electric
47 CVEs0 on KEV0 new
IG9.8
Interactive Graphical Scada System
Schneider-electric
43 CVEs0 on KEV0 new
MM9.8
Modicon M580 Firmware
Schneider-electric
41 CVEs0 on KEV0 new
MM9.8
Modicon M340 Firmware
Schneider-electric
39 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp342020 Firmware
Schneider-electric
32 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp3420302 Firmware
Schneider-electric
28 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp341000 Firmware
Schneider-electric
27 CVEs0 on KEV0 new
EC9.8
Ecostruxure Control Expert
Schneider-electric
26 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp342000 Firmware
Schneider-electric
25 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp3420102 Firmware
Schneider-electric
25 CVEs0 on KEV0 new
MQ9.8
Modicon Quantum Firmware
Schneider-electric
25 CVEs0 on KEV0 new
ET9.8
Easergy T300 Firmware
Schneider-electric
24 CVEs0 on KEV0 new
MP9.8
Modicon Premium Firmware
Schneider-electric
23 CVEs0 on KEV0 new
1F9.8
140cpu65150 Firmware
Schneider-electric
20 CVEs0 on KEV0 new
EC9.8
Evlink City Evc1s22p4 Firmware
Schneider-electric
18 CVEs0 on KEV0 new
EC9.8
Evlink City Evc1s7p4 Firmware
Schneider-electric
18 CVEs0 on KEV0 new
EP9.8
Evlink Parking Evf2 Firmware
Schneider-electric
18 CVEs0 on KEV0 new
EP9.8
Evlink Parking Evw2 Firmware
Schneider-electric
18 CVEs0 on KEV0 new
ES9.8
Evlink Smart Wallbox Evb1a Firmware
Schneider-electric
18 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp3420102cl Firmware
Schneider-electric
17 CVEs0 on KEV0 new
SF9.8
Spacelynk Firmware
Schneider-electric
17 CVEs0 on KEV0 new
MM9.8
Modicon M221 Firmware
Schneider-electric
16 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp342020h Firmware
Schneider-electric
16 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp3420302cl Firmware
Schneider-electric
16 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp3420302h Firmware
Schneider-electric
16 CVEs0 on KEV0 new
EP9.8
EcoStruxure™ Process Expert
Schneider Electric
15 CVEs0 on KEV0 new
IF9.8
Ibp1110-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Ibp219-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Ibp319-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Ibp519-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Ibps110-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp1110-1 Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp1110-1e Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp1110-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp219-1 Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp219-1e Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp219-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp319-1 Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp319-1e Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp319-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp519-1 Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp519-1e Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imp519-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imps110-1e Firmware
Schneider-electric
15 CVEs0 on KEV0 new
IF9.8
Imps110-1er Firmware
Schneider-electric
15 CVEs0 on KEV0 new
BF9.8
Bmxnoe0100 Firmware
Schneider-electric
14 CVEs0 on KEV0 new
BF9.8
Bmxnoe0110 Firmware
Schneider-electric
14 CVEs0 on KEV0 new
BF9.8
Bmxnor0200h Firmware
Schneider-electric
14 CVEs0 on KEV0 new
EP9.8
Ecostruxure Power Monitoring Expert
Schneider-electric
14 CVEs0 on KEV0 new
1F9.8
140cpu65160 Firmware
Schneider-electric
13 CVEs0 on KEV0 new
EP9.8
Evlink Parking Ev.2 Firmware
Schneider-electric
13 CVEs0 on KEV0 new
MM9.8
Modicon M340 Bmxp342030 Firmware
Schneider-electric
13 CVEs0 on KEV0 new
1F9.8
140cpu65260 Firmware
Schneider-electric
12 CVEs0 on KEV0 new
Recent CVEs
| CVE | Product | CVSS | Published | Summary |
|---|---|---|---|---|
| CVE-2026-102250 | SR Sage RTU 1410 Schneider Electric | 8.6 | Oct 13 | CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware… |
| CVE-2026-3869 | MM Modicon M580 Safety Schneider Electric | 9.2 | Sep 11 | CWE-303 : Incorrect Implementation of Authentication Algorithm vulnerability exists that could cause loss of confidentiality, integrity and availability of the PLC provided an… |
| CVE-2026-81861 | S4 SCADAPack 47xi Schneider Electric | 5.9 | Sep 11 | CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality |
| CVE-2026-77120 | PT PowerLogic T300 Schneider Electric | 8.7 | Sep 9 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause privilege escalation to root and… |
| CVE-2026-19233 | EI EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Schneider Electric | 8.6 | Sep 9 | CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized command execution and disclosure of server data when an attacker with a privileged… |
| CVE-2026-8044 | EI EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Schneider Electric | 8.6 | Sep 9 | CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability exists that could cause remote code execution by an attacker with a… |
| CVE-2026-13348 | PS PowerChute™ Serial Shutdown Schneider Electric | 6.9 | Sep 1 | CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an… |
| CVE-2026-13337 | N5 NetBotz 5 - 750/755 Schneider Electric | 5.1 | Sep 1 | CWE-564: SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the… |
| CVE-2026-13336 | N5 NetBotz 5 - 750/755 Schneider Electric | 7.3 | Sep 1 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux Operating system… |
| CVE-2024-10085 | EO EcoStruxure™ OPC UA Server Expert Schneider Electric | 8.2 | Sep 1 | CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause denial of service of the OPC UA communication platform when a large number of… |
| CVE-2026-12927 | ID IGSS Definition (Def.exe) Schneider Electric | 8.4 | Jul 29 | CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is imported to IGSS… |
| CVE-2026-0667 | S5 SCADAPack 57x Schneider Electric | 9.3 | Jul 29 | CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity… |
| CVE-2026-14354 | EC EcoStruxure™ Cybersecurity Admin Expert Schneider Electric | 8.7 | Jul 29 | CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to… |
| CVE-2026-9718 | PP PowerLogic™ P7 Schneider Electric | 6.5 | Jun 25 | CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a… |
| CVE-2026-9717 | PP PowerLogic™ P7 Schneider Electric | 7.2 | Jun 25 | CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated… |
| CVE-2026-9716 | PP PowerLogic™ P7 Schneider Electric | 7.5 | Jun 25 | CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when… |
| CVE-2026-9651 | SD Saitel DP Remote Terminal Unit & Controller Schneider Electric | 4.4 | Jun 25 | CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an… |
| CVE-2026-9650 | ET EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Schneider Electric | 7.5 | Jun 25 | CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses… |
| CVE-2026-8045 | EI EcoStruxure™ IT Data Center Expert Schneider Electric | 6.5 | Jun 9 | CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a… |
| CVE-2026-6332 | EM Ecostruxure™ Machine Expert HVAC Schneider Electric | 7.5 | May 14 | Clear Text Storage of Sensitive Information on EcoStruxure™ Machine Expert HVAC |
| CVE-2026-6866 | EP EcoStruxure™ Panel Server Schneider Electric | 7.5 | May 12 | Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure™ Panel Server |
| CVE-2026-6865 | ET EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Schneider Electric | 7.1 | May 12 | Improper Limitation of a Pathname to a Restricted Directory Vulnerability on Multiple Products |
| CVE-2026-4827 | EM Easergy MiCOM C264 Schneider Electric | 8.7 | May 12 | Insufficient Entropy vulnerability on Multiple Products |
| CVE-2026-2401 | PS PowerChute™ Serial Shutdown Schneider Electric | 5.0 | Apr 14 | CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious… |
| CVE-2026-2400 | PS PowerChute™ Serial Shutdown Schneider Electric | 4.3 | Apr 14 | CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the… |
| CVE-2026-2403 | PS PowerChute™ Serial Shutdown Schneider Electric | 4.3 | Apr 14 | CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user… |
| CVE-2026-2405 | PS PowerChute™ Serial Shutdown Schneider Electric | 6.5 | Apr 14 | CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the… |
| CVE-2026-2402 | PS PowerChute™ Serial Shutdown Schneider Electric | 5.3 | Apr 14 | CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary… |
| CVE-2026-2404 | PS PowerChute™ Serial Shutdown Schneider Electric | 5.3 | Apr 14 | CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request… |
| CVE-2026-2399 | PS PowerChute™ Serial Shutdown Schneider Electric | 6.1 | Apr 14 | CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web… |
| CVE-2026-4832 | EM Easergy MiCOM P443, P445, P446, P543, P544, P545, P546 Schneider Electric | 6.9 | Apr 14 | CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to… |
| CVE-2026-2273 | EA EcoStruxure™ Automation Expert Schneider Electric | 8.2 | Mar 10 | CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could… |
| CVE-2026-1286 | EF EcoStruxure™ Foxboro DCS Schneider Electric | 6.5 | Mar 10 | CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an… |
| CVE-2025-13902 | MC Modicon Controllers M241/M251 Schneider Electric | 5.4 | Mar 10 | CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have… |
| CVE-2025-13901 | MM Modicon M262 Schneider Electric | 5.3 | Mar 10 | CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends… |
| CVE-2025-11739 | EP EcoStruxure™ Power Monitoring Expert (PME) Schneider Electric | 7.8 | Mar 10 | CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker… |
| CVE-2025-13957 | EI EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) Schneider Electric | 7.5 | Mar 10 | CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator… |
| CVE-2026-1226 | EB EcoStruxure Building Operation Workstation Schneider Electric | 7.0 | Feb 11 | CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted… |
| CVE-2026-1227 | EB EcoStruxure Building Operation Workstation Schneider Electric | 7.0 | Feb 11 | CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or… |
| CVE-2025-13905 | EP EcoStruxure™ Process Expert for AVEVA System Platform Schneider Electric | 7.0 | Jan 29 | CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are… |
| CVE-2025-13845 | EP EcoStruxure Power Build Rapsody Schneider Electric | 7.8 | Jan 15 | CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody |
| CVE-2025-13844 | EP EcoStruxure Power Build Rapsody Schneider Electric | 5.3 | Jan 15 | CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody |
| CVE-2024-9409 | PP Powerlogic Pm5341 Firmware Schneider-electric | 7.5 | Nov 13 | CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP… |
| CVE-2024-10575 | EI Ecostruxure IT Gateway Schneider-electric | 9.8 | Nov 13 | CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices |
| CVE-2024-8422 | ZS Zelio Soft 2 Schneider-electric | 7.8 | Oct 8 | CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when application user opens a… |
| CVE-2024-8306 | VD Vijeo Designer Schneider-electric | 7.8 | Sep 11 | CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the workstation when… |
| CVE-2024-6407 | WF Whc-5918a Firmware Schneider-electric | 7.5 | Jul 11 | CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device |
| CVE-2024-6528 | MM Modicon M251 Firmware Schneider-electric | 6.1 | Jul 11 | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site… |
| CVE-2024-5681 | EF Ecostruxure Foxboro Dcs Control Core Services Schneider-electric | 7.8 | Jul 11 | CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with… |
| CVE-2024-5680 | EF Ecostruxure Foxboro Dcs Control Core Services Schneider-electric | 5.5 | Jul 11 | CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program… |
| CVE-2024-5679 | EF Ecostruxure Foxboro Dcs Control Core Services Schneider-electric | 7.1 | Jul 11 | CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or kernel memory leak when a malicious actor with local user access crafts a… |
| CVE-2024-2602 | FS Foxrtu Station Schneider-electric | 7.8 | Jul 11 | CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user… |
| CVE-2024-5559 | PP Powerlogic P5 Firmware Schneider-electric | 6.8 | Jun 12 | CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay… |
| CVE-2024-2747 | ES Easergy Studio Schneider-electric | 7.8 | Jun 12 | CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could cause privilege escalation when a valid user replaces a trusted file name on the… |
| CVE-2024-0865 | EI Ecostruxure IT Gateway Schneider-electric | 7.8 | Jun 12 | CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user |
| CVE-2024-5560 | SR Sage Rtu Firmware Schneider-electric | 7.5 | Jun 12 | CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request |
| CVE-2024-5558 | SA Spacelogic As-b Firmware Schneider-electric | 6.4 | Jun 12 | CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account |
| CVE-2024-5557 | SA Spacelogic As-b Firmware Schneider-electric | 4.5 | Jun 12 | CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs |
| CVE-2024-37040 | SR Sage Rtu Firmware Schneider-electric | 8.1 | Jun 12 | CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a… |
| CVE-2024-37039 | SR Sage Rtu Firmware Schneider-electric | 7.5 | Jun 12 | CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request |