Medium severity · published Jun 9, 2026
CVE-2026-8045
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a…
6.5
CVSS
0.2%
EPSS
No
On KEV
Description
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Confidentiality
High
Integrity
None
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 14% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
EI
EcoStruxure™ IT Data Center Expert · Schneider Electric
v9.1.1 and Prior · source: vendor
SD
Struxureware Data Center Expert · Schneider-electric
before 9.1.2 · source: NVD
In the news
ThreatIntelMedium
Schneider Electric EcoStruxure IT Data Center Expert
View CSAF
Summary
Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure.
The following versions of Schneider Electric EcoStruxure IT Data Center Expert are affected:
EcoStruxure IT Data Center Expert vers:intdot/<=9.1.1, 9.1.2 (CVE-2026-8045)
CVSS
Vendor
Equipment
Vulnerabilities
v3 6.5
Schneider Electric
Schneider Electric EcoStruxure IT Data Center Expert
Improper Restriction of XML External Entity Reference
Background
Critical Infrastructure Sectors: Information Technology, Critical Manufacturing, Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: France
Vulnerabilities
Expand All +
CVE-2026-8045
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints
View CVE Details
Affected Products
Schneider Electric EcoStruxure IT Data Center Expert
Vendor: Schneider Electric
Product Version: EcoStruxure IT Data Center Expert (Formerly k...
Jun 30, 2026·CISA Advisories
Affected product
EI
EcoStruxure™ IT Data Center Expert
Schneider Electric