EP
Product
EcoStruxure™ Power Monitoring Expert
by Schneider Electric · last CVE Mar 10, 2026
17
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 1High 9Medium 7Low 0
Watch

Add EcoStruxure™ Power Monitoring Expert to your stack to get only the CVEs that touch what you run.

CVECVSSEPSSPublishedSummary · affected versions
CVE-2023-5391
9.8
1%
Oct 4
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted…
Affected: All versions – prior to application of Hotfix-145271
CVE-2023-28003
8.8
0%
Apr 18
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate…
Affected: All through PME 2022
CVE-2022-22727
8.8
1%
Feb 4
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or…
Affected: through 2020
CVE-2021-22827
8.8
1%
Jan 28
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload
Affected: through 9.0
CVE-2021-22826
8.8
1%
Jan 28
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload
Affected: through 9.0
CVE-2020-7547
8.8
1%
Dec 1
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)…
Affected: 7.0; 8.0; 9.0
CVE-2025-11739
7.8
0%
Mar 10
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker…
Affected: 2022; 2023; 2023; 2024; 2024
CVE-2024-2229
7.8
0%
Mar 18
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution when a malicious project file is loaded into the application by a valid user
Affected: 0
CVE-2024-9005
7.3
0%
Oct 8
CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web…
Affected: before 2022
CVE-2020-7545
7.2
2%
Dec 1
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)…
Affected: 7.0; 8.0; 9.0
CVE-2022-22726
6.5
1%
Feb 4
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system…
Affected: through 2020
CVE-2023-5987
6.1
0%
Nov 15
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting…
Affected: 2020; 2020; 2020; 2021; 2021
CVE-2023-5986
6.1
0%
Nov 15
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack
Affected: 2020; 2020; 2020; 2021; 2021
CVE-2018-7797
6.1
1%
Dec 17
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions),…
Affected: 8.2; 9.0
CVE-2022-22804
5.4
0%
Feb 4
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change…
Affected: through 2020
CVE-2020-7546
5.4
1%
Dec 1
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security…
Affected: 7.0; 8.0; 9.0
CVE-2025-6788
5.3
0%
Jul 11
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources to the wrong control sphere, providing other authenticated users with…
Affected: 2023 before All; 2023 R2 before All; 2024 before All; 2024 R2 before All
Showing 17