MQ
Product
Modicon Quantum Firmware
25
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 6High 16Medium 3Low 0
Watch
Add Modicon Quantum Firmware to your stack to get only the CVEs that touch what you run.
| CVE | CVSS | Published | Summary · affected versions |
|---|---|---|---|
| CVE-2019-6808 | 9.8 | May 22 | A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code… Affected: through 3.60 |
| CVE-2018-7847 | 9.8 | May 22 | A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service… Affected: All versions, or not specified |
| CVE-2018-7846 | 9.8 | May 22 | A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium… Affected: All versions, or not specified |
| CVE-2018-7842 | 9.8 | May 22 | A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an… Affected: All versions, or not specified |
| CVE-2019-6816 | 9.1 | May 22 | In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using… Affected: All versions, or not specified |
| CVE-2019-6815 | 9.1 | May 22 | In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the… Affected: All versions, or not specified |
| CVE-2019-6828 | 7.5 | Sep 17 | A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions),… Affected: All versions, or not specified |
| CVE-2019-6809 | 7.5 | Sep 17 | A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all… Affected: All versions, or not specified |
| CVE-2019-6807 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of… Affected: All versions, or not specified |
| CVE-2019-6806 | 7.5 | May 22 | A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of… Affected: All versions, or not specified |
| CVE-2018-7857 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of… Affected: before 3.60 |
| CVE-2018-7856 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of… Affected: All versions, or not specified |
| CVE-2018-7855 | 7.5 | May 22 | A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service… Affected: All versions, or not specified |
| CVE-2018-7854 | 7.5 | May 22 | A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service… Affected: All versions, or not specified |
| CVE-2018-7853 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when… Affected: All versions, or not specified |
| CVE-2018-7844 | 7.5 | May 22 | A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of… Affected: All versions, or not specified |
| CVE-2019-6819 | 7.5 | May 22 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the… Affected: All versions, or not specified |
| CVE-2018-7852 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when… Affected: All versions, or not specified |
| CVE-2018-7849 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of… Affected: All versions, or not specified |
| CVE-2018-7848 | 7.5 | May 22 | A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of… Affected: All versions, or not specified |
| CVE-2018-7845 | 7.5 | May 22 | A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of… Affected: All versions, or not specified |
| CVE-2018-7843 | 7.5 | May 22 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when… Affected: All versions, or not specified |
| CVE-2019-6821 | 6.5 | May 22 | CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware… Affected: All versions, or not specified |
| CVE-2018-7788 | 6.5 | May 22 | A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40 Affected: before 2.40 |
| CVE-2018-7850 | 5.3 | May 22 | A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which… Affected: All versions, or not specified |
Showing 25