SB
Product
SICORE Base system
by Siemens · last CVE Jul 9, 2026
6
CVEs
0
On KEV
9.0
Max CVSS
0
New 30D
VulnerabilityHigh
Siemens SICAM 8
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/<26.20 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) SICORE Base system vers:intdot/<26.20.0 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens SICAM 8 Active Debug Code, Initialization of a Resource with an Insecure Default, Unverified Password Change Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-54798 The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/C...
Jul 16, 2026·CISA Advisories
VulnerabilityHigh
Siemens SICAM 8 Products
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - RTUM85 for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE - RTUM85 Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 Products are affected: CPCI85 Central Processing/Communication vers:intdot/<26.10 (CVE-2026-27663, CVE-2026-27664) RTUM85 RTU Base vers:intdot/<26.10 (CVE-2026-27663) SICORE Base system vers:intdot/<26.10.0 (CVE-2026-27664) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens SICAM 8 Products Allocation of Resources Without Limits or Throttling, Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-27663 The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality. View CVE Details Affe...
Apr 2, 2026·CISA Advisories