Medium severity · published Jul 9, 2026
CVE-2026-54800
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0)
4.8
CVSS
0.2%
EPSS
No
On KEV
Description
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application ships with a default configuration that disables all OPC UA security mechanisms. This could allow an attacker to gain unauthorized access and control over critical system functions.
CVSS vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 14% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SB
SICORE Base system · Siemens
before V26.20.0 · source: vendor
In the news
VulnerabilityHigh
Siemens SICAM 8
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/&lt;26.20 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) SICORE Base system vers:intdot/&lt;26.20.0 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens SICAM 8 Active Debug Code, Initialization of a Resource with an Insecure Default, Unverified Password Change Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-54798 The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions. View CVE Details Affected Products Siemens SICAM 8 Vendor: Siemens Product Version: CPCI85 Central Processing/C...
Jul 16, 2026·CISA Advisories
Affected product
CC
CPCI85 Central Processing/Communication
Siemens
More from CPCI85 Central Processing/Communication
9.0
CVE-2024-3596
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
7.5
CVE-2026-27664
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0)
7.2
CVE-2026-54801
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0)
6.7
CVE-2026-54799
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0)
6.5
CVE-2026-54798
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0)