FH
Product
FH1203
23
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 14High 9Medium 0Low 0
Watch
Add FH1203 to your stack to get only the CVEs that touch what you run.
| CVE | CVSS | Published | Summary · affected versions |
|---|---|---|---|
| CVE-2024-30602 | 9.8 | Mar 28 | Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function Affected: 2.0.1.6 |
| CVE-2023-38931 | 9.8 | Aug 7 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13… Affected: V2.0.1.6 |
| CVE-2023-38933 | 9.8 | Aug 7 | Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were… Affected: V2.0.1.6 |
| CVE-2023-38934 | 9.8 | Aug 7 | Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function Affected: V2.0.1.6 |
| CVE-2023-38936 | 9.8 | Aug 7 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205… Affected: V2.0.1.6 |
| CVE-2023-38940 | 9.8 | Aug 7 | Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function Affected: V2.0.1.6 |
| CVE-2023-37706 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function Affected: V2.0.1.6 |
| CVE-2023-37707 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function Affected: V2.0.1.6 |
| CVE-2023-37700 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function Affected: V2.0.1.6 |
| CVE-2023-37701 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function Affected: V2.0.1.6 |
| CVE-2023-37702 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function Affected: v2.0.1.6 |
| CVE-2023-37703 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function Affected: V2.0.1.6 |
| CVE-2023-37704 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function Affected: V2.0.1.6 |
| CVE-2023-37705 | 9.8 | Jul 10 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function Affected: V2.0.1.6 |
Showing 14