SN
Product
Simcenter Nastran
10
CVEs
0
On KEV
7.8
Max CVSS
0
New 30D
VulnerabilityHigh
Siemens Simcenter Nastran
View CSAF
Summary
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Simcenter Nastran are affected:
Simcenter Femap vers:intdot/<2606 (CVE-2026-59086)
Simcenter Nastran vers:intdot/<2606 (CVE-2026-59086)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.8
Siemens
Siemens Simcenter Nastran
Stack-based Buffer Overflow
Background
Critical Infrastructure Sectors: Critical Manufacturing, Defense Industrial Base, Energy, Healthcare and Public Health, Transportation Systems
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-59086
The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
View CVE Details
Affected Products
Siemens Simcenter Nastran
Vendor: Siemens
Product Version: Simcenter ...
Aug 18, 2026·CISA Advisories
VulnerabilityMedium
Siemens Simcenter Femap and Nastran
View CSAF
Summary
Siemens Simcenter Femap and Nastran is affected by multiple file parsing vulnerabilities that could be triggered when the application reads files in NDB and XDB formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Simcenter Femap and Nastran are affected:
Simcenter Femap vers:intdot/<2512 (CVE-2026-23715, CVE-2026-23716, CVE-2026-23717, CVE-2026-23718, CVE-2026-23719, CVE-2026-23720)
Simcenter Nastran vers:intdot/<2512 (CVE-2026-23715, CVE-2026-23716, CVE-2026-23717, CVE-2026-23718, CVE-2026-23719, CVE-2026-23720)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.8
Siemens
Siemens Simcenter Femap and Nastran
Out-of-bounds Write, Out-of-bounds Read, Heap-based Buffer Overflow
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-23715
The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
View CVE Details
Affected Products
Sie...
Feb 17, 2026·CISA Advisories