CVECVSSEPSSPublishedSummary · affected versions
CVE-2017-12069
8.2
3%
Aug 30
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367
Affected: through 8.1
CVE-2016-7165
6.4
0%
Nov 15
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software…
Affected: 8.0; 8.1; 8.2
CVE-2017-14023
4.9
4%
Nov 6
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions
Affected: 8.1; 8.2
CVE-2014-8552
–
2%
Nov 26
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13…
Affected: 7.1; 7.1; 8.0; 8.0; 8.1
CVE-2014-8551
–
5%
Nov 26
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13…
Affected: 7.1; 7.1; 8.0; 8.0; 8.1
CVE-2014-4686
–
1%
Jul 24
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to…
Affected: through 8.0; 7.1; 8.0
CVE-2014-4685
–
0%
Jul 24
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control
Affected: through 8.0; 7.1; 8.0
CVE-2014-4684
–
1%
Jul 24
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433
Affected: through 8.0; 7.1; 8.0
CVE-2014-4683
–
1%
Jul 24
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS…
Affected: through 8.0; 7.1; 8.0
CVE-2014-4682
–
2%
Jul 24
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request
Affected: through 8.0; 7.1; 8.0
CVE-2013-3959
–
1%
Jun 14
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names…
Affected: through 8.0; 8.0
CVE-2013-3958
–
2%
Jun 14
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which…
Affected: through 8.0; 8.0
CVE-2013-3957
–
2%
Jun 14
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows…
Affected: through 8.0; 8.0
CVE-2013-0679
–
2%
Mar 21
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to…
Affected: through 8.0; 7.1
CVE-2013-0678
–
2%
Mar 21
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for…
Affected: through 8.0
CVE-2013-0677
–
2%
Mar 21
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of…
Affected: through 8.0; 7.1
CVE-2013-0676
–
2%
Mar 21
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials,…
Affected: through 8.0; 7.1
CVE-2013-0675
–
1%
Mar 21
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote…
Affected: through 8.0; 7.1
CVE-2013-0674
–
3%
Mar 21
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute…
Affected: through 8.0; 7.1
CVE-2012-3034
–
2%
Sep 18
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters…
Affected: 8.0
CVE-2012-3032
–
2%
Sep 18
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL…
Affected: 8.0
CVE-2012-3031
–
2%
Sep 18
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to…
Affected: 8.0
CVE-2012-3030
–
3%
Sep 18
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control,…
Affected: 8.0
CVE-2012-3028
–
1%
Sep 18
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack…
Affected: 8.0
CVE-2012-3015
–
0%
Jul 26
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges…
Affected: through 7.1
Showing 25