MC
Product
Mirth Connect
On CISA KEVExploited in the wildRansomware-linked
4
CVEs
1
On KEV
9.8
Max CVSS
0
New 30D
VulnerabilityHigh
NextGen Healthcare Mirth Connect
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker to exfiltrate date or cause a denial-of-service condition.
The following versions of NextGen Healthcare Mirth Connect are affected:
Mirth Connect <=v4.7.1 (CVE-2026-82583, CVE-2026-78224, CVE-2026-82578)
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.3
NextGen Healthcare
NextGen Healthcare Mirth Connect
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Restriction of XML External Entity Reference
Background
Critical Infrastructure Sectors: Healthcare and Public Health
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-82583
NextGen Connect (Mirth Connect) versions 4.7.1 and earlier allow an authenticated user to execute arbitrary SQL through a Database Connector API, which could result in disclosure of stored credentials for connected systems, arbitrary file write, and a denial-of-service condition.
View CVE Details
Affected Products
NextGen Healthcare Mirth Connect
Vendor: NextGen Healthcare
Product Version: NextGen Healthcare Mirth Connect: <=v4.7.1
Product Status: known_affected
Remediations
Vendor fix NextGen recommends users update Mirth Connect v4.7.2 or later. Users can download the latest version from the NextGen Healthcare customer portal....
Sep 10, 2026·CISA Advisories