InterSystems Corporation InterSystems IRIS for Health
View CSAF
Summary
Successful exploitation of this vulnerability could allow an attacker to view transmitted data and use that data to log into the device.
The following versions of InterSystems Corporation InterSystems IRIS for Health are affected:
InterSystems IRIS for Health 2026.2.0.221, 2026.1.0.235, 2025.3.0.226 (CVE-2026-111594, CVE-2026-111594, CVE-2026-111594)
CVSS
Vendor
Equipment
v3 8.1
InterSystems Corporation
InterSystems IRIS for Health
1 Vulnerability
Cleartext Transmission of Sensitive Information
Background
Critical Infrastructure Sectors: Healthcare and Public Health
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
CVE-2026-111594
InterSystems IRIS for Health has TLS/SSL encryption turned off by default, which may enable an attacker to view transmitted data and use that data to log into the device.
Read More
3 Affected Products
InterSystems Corporation InterSystems IRIS for Health: 2026.2.0.221
Product Status: known_affected
Remediations
Mitigation InterSystems recommends users configure IRIS superserver to require SSL/TLS: https://docs.intersystems.com/irislatest/csp/docbook/DocBook.UI.Page.cls?KEY=ROARS_gsecuring_checklist Note that there are three settings: "Disabled", which means that client communications do not use TLS. "Enabled", which means that client communications may use T...