Sigma Spectrum Infusion System Firmware
by Baxter · last CVE Jun 29, 2020
10
CVEs
0
On KEV
9.8
Max CVSS
0
New 30D
Severity mix
Critical 8High 0Medium 1Low 1
Watch

Add Sigma Spectrum Infusion System Firmware to your stack to get only the CVEs that touch what you run.

CVECVSSEPSSPublishedSummary · affected versions
CVE-2020-12047
9.8
2%
Jun 29
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an…
Affected: 8.0
CVE-2020-12045
9.8
2%
Jun 29
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023…
Affected: 8.0
CVE-2020-12043
9.8
2%
Jun 29
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is…
Affected: 8.0
CVE-2020-12040
9.8
1%
Jun 29
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated…
Affected: 6.0 through 6.05; 8.0
CVE-2014-5433
9.8
2%
Mar 26
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System…
Affected: 6.05
CVE-2014-5432
9.8
3%
Mar 26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication
Affected: 6.05
CVE-2014-5434
9.8
2%
Mar 26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the…
Affected: 6.05
CVE-2020-12041
9.4
1%
Jun 29
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary…
Affected: 8.0
CVE-2014-5431
6.8
0%
Mar 26
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic…
Affected: 6.05
CVE-2020-12039
2.4
0%
Jun 29
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when…
Affected: 6.0 through 6.05; 8.0
Showing 10