Medium severity · published Aug 11, 2026
CVE-2026-66098
Mira Hormone Monitor, Mira Android App Missing authentication for critical function
6.5
CVSS
0.3%
EPSS
No
On KEV
Description
The Mira hormone monitor device firmware accepts a 0x01 write from any BLE central without authentication, causing the device to reboot into bootloader mode. An attacker could cause a denial-of-service condition or disrupt ovulation tracking and fertility monitoring workflow.
CVSS vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
None
Integrity
None
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.3% · higher than 25% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
In the news
VulnerabilityCritical
Mira Hormone Monitor, Mira Android App
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access unauthorized health profile information, make changes to health information, cause a denial-of-service condition, disclose session token information, and obtain control of user accounts. The following versions of Mira Hormone Monitor, Mira Android App are affected: Mira Monitor Firmware 1.7.1.47 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) Mira Android App 4.5.15.4 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) CVSS Vendor Equipment Vulnerabilities v3 9.8 Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Hormone Monitor, Mira Android App Missing Authentication for Critical Function, Authentication Bypass by Spoofing, Use of Hard-coded Credentials, Weak Authentication, Improper Restriction of Excessive Authentication Attempts, Reliance on Untrusted Inputs in a Security Decision, Use of GET Request Method With Sensitive Query Strings Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-66875 In the Mira hormone monitor device firmware v1.7.1.47 build 01070147, a remote unauthent...
Aug 11, 2026·CISA Advisories
Affected product
MA
Mira Android App
Quanovate Tech Inc. (operating as Mira / Mira Care)
More from Mira Android App
9.8
CVE-2026-68067
Mira Hormone Monitor, Mira Android App Weak Authentication
9.1
CVE-2026-67568
Mira Hormone Monitor, Mira Android App Use of Hard-coded Credentials
8.8
CVE-2026-66875
Mira Hormone Monitor, Mira Android App Missing authentication for critical function
7.4
CVE-2026-67558
Mira Hormone Monitor, Mira Android App Authentication bypass by spoofing
6.5
CVE-2026-66832
Mira Hormone Monitor, Mira Android App Use of GET request method with sensitive query strings