Medium severity · published Sep 8, 2026
CVE-2026-58113
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607),…
6.1
CVSS
0.4%
EPSS
No
On KEV
Description
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)0.4% · higher than 33% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
TV
Teamcenter V2412 · Siemens
before V2412.0013 · source: vendor
TV
Teamcenter V2506 · Siemens
before V2506.0010 · source: vendor
TV
Teamcenter V2512 · Siemens
before V2512.2607 · source: vendor
TV
Teamcenter V2606 · Siemens
before V2606.2607 · source: vendor
In the news
AdvisoryMedium
Siemens Teamcenter
View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (/auth/) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2412 vers:intdot/&lt;2412.0013 (CVE-2026-58113) Teamcenter V2506 vers:intdot/&lt;2506.0010 (CVE-2026-58113) Teamcenter V2512 vers:intdot/&lt;2512.2607 (CVE-2026-58113) Teamcenter V2606 vers:intdot/&lt;2606.2607 (CVE-2026-58113) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens Teamcenter Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-58113 Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into t...
Sep 15, 2026·CISA Advisories
Affected product
TV
Teamcenter V2412
Siemens
More from Teamcenter V2412
7.5
CVE-2026-33893
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009),…
6.1
CVE-2026-33862
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009),…