Medium severity · published Dec 18, 2019
CVE-2019-18995
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to…
5.3
CVSS
2.1%
EPSS
No
On KEV
Description
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
None
Integrity
None
Availability
Low
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)2.1% · higher than 82% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
PP
Pb610 Panel Builder 600 · Abb
through 2.8.0.424 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2019-18995
CVE.org
https://www.cve.org/CVERecord?id=CVE-2019-18995
Third Party Advisory
http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466&LanguageCode=en&DocumentPartId=&Action=Launch
More from Pb610 Panel Builder 600
7.8
CVE-2019-18996
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker…
7.5
CVE-2019-18997
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file
6.5
CVE-2019-18994
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application…