Medium severity · published Dec 18, 2019
CVE-2019-18994
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application…
6.5
CVSS
0.6%
EPSS
No
On KEV
Description
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
None
Integrity
None
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.6% · higher than 49% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
PP
Pb610 Panel Builder 600 · Abb
through 2.8.0.424 · source: NVD
Affected product
PP
Pb610 Panel Builder 600
Abb
More from Pb610 Panel Builder 600
7.8
CVE-2019-18996
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker…
7.5
CVE-2019-18997
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file
5.3
CVE-2019-18995
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to…