Home › Intelligence › Brief
VULNERABILITY BRIEF 🟡 Medium Vulnerability

Denial‑of‑Service Vulnerability (CVE‑2024‑7322) Impacts Siemens SENTRON 3NA COM Fuse Industrial Controllers

A CVE‑2024‑7322 flaw in Siemens SENTRON 3NA COM Fuse firmware < 5.2 lets an attacker trigger a denial‑of‑service by sending a crafted ZigBee re‑join response. The issue affects critical‑infrastructure deployments and underscores the importance of timely patching and auditable control evidence.

Verisq™ Intelligence · 📅 October 23, 2026 · 📰 cisa.gov
🟡
Severity
Medium
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
2 sector(s)
✅
Actions
3 recommended
📰
Source
cisa.gov

Denial‑of‑Service Vulnerability (CVE‑2024‑7322) Impacts Siemens SENTRON 3NA COM Fuse Industrial Controllers

What It Is — Siemens SENTRON 3NA COM Fuse firmware versions prior to 5.2 contain an improper verification of the source of a ZigBee network‑management message. An attacker who can inject an unsolicited encrypted re‑join response can force the device to change its node ID, resulting in a denial‑of‑service (DoS) condition.

Exploitability — CVSS v3.1 base score 5.8 (Medium). No public exploit code has been released, but the vulnerability is network‑reachable on any segment that permits ZigBee management traffic.

Affected Products — Siemens SENTRON 3NA COM Fuse < v5.2 (industrial control equipment used in energy, manufacturing, transportation, and other critical infrastructure).

Why It Matters for Trust & Control Assurance

  • Demonstrates the need for continuous monitoring of firmware versions and rapid evidence collection to prove timely patching.
  • Highlights gaps in network‑segmentation and source‑validation controls that map to multiple frameworks (e.g., NIST CSF 2.0 “Detect” and “Respond” functions).
  • Provides a concrete incident that buyers will scrutinize when demanding defensible audit trails for critical‑infrastructure assets.

Recommended Actions

  • Apply Siemens‑provided firmware update to version 5.2 or later.
  • Verify that ZigBee management traffic is confined to isolated, monitored network zones.
  • Augment logging of ZigBee communication events and retain logs for audit purposes.
  • Incorporate the patch‑status check into your continuous control‑monitoring platform.

Source: CISA Advisory – ICSA‑26‑295‑05

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-295-05 ↗

This Verisq Intelligence Brief is an independent analysis. Read the original reporting at the link above.

Vulnerability exposure

Is this CVE in your supply chain?

Verisq matches published vulnerabilities against the software your vendors run, so you know which relationships this touches before the next review.

See vendor exposure →