Medium severity · published Oct 13, 2026
CVE-2026-63356
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page
6.1
CVSS
0.2%
EPSS
No
On KEV
Description
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Attacker-controlled JavaScript could be executed in the user’s browser session when the resulting error message is displayed.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 8% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
In the news
VulnerabilityHigh
Siemens SIMATIC S7 PLCs Web Server
View CSAF Summary SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7 PLCs Web Server are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP-1 PN (6ES...
Oct 22, 2026·CISA Advisories
Affected product
SD
SIMATIC Drive Controller CPU 1504D TF
Siemens
More from SIMATIC Drive Controller CPU 1504D TF
9.6
CVE-2026-63354
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page
9.6
CVE-2026-63353
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page
9.6
CVE-2026-63350
Affected devices do not properly restrict executable content contained in imported trace files
9.1
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface
9.1
CVE-2026-25786
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface