High severity · published Aug 19, 2026
CVE-2026-16933
Power System Integer Overflow
8.2
CVSS
0.2%
EPSS
No
On KEV
Description
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Confidentiality
High
Integrity
High
Availability
High
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 6% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
PS
Power Systems Firmware · IBM
FW1120.00; FW1110.00 through FW1110.30; FW1060.00 through FW1060.80; FW950.00 through FW950.H2; OP940.00 through OP940.a1; OP940.00 through OP940.81 · source: vendor
PH
Power Hardware Management Console (7063-cr2) Firmware · Ibm
op940 before op940.82 · source: NVD
PS
Power System Ac922 (8335-gth) Firmware · Ibm
op940 before op940.a2 · source: NVD
PS
Power System Ac922 (8335-gtx) Firmware · Ibm
op940 before op940.a2 · source: NVD
PS
Power System E1050 (9043-mrx) Firmware · Ibm
fw1060.00 before fw1060.81 · source: NVD
PS
Power System E1080 (9080-hex) Firmware · Ibm
fw1060.00 before fw1060.81 · source: NVD
PS
Power System E1150 (9043-mru) Firmware · Ibm
fw1110.00 before fw1110.31; fw1120.00 · source: NVD
PS
Power System E1180 (9080-heu) Firmware · Ibm
fw1110.00 before fw1110.31; fw1120.00 · source: NVD
PS
Power System E950 (9040-mr9) Firmware · Ibm
fw950.00 before fw950.h3 · source: NVD
PS
Power System E980 (9080-m9s) Firmware · Ibm
fw950.00 before fw950.h3 · source: NVD
PS
Power System H922 (9223-22s) Firmware · Ibm
fw950.00 before fw950.h3 · source: NVD
PS
Power System H924 (9223-42s) Firmware · Ibm
fw950.00 before fw950.h3 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2026-16933
CVE.org
https://www.cve.org/CVERecord?id=CVE-2026-16933
Vendor Advisory
https://www.ibm.com/support/pages/node/7283216
More from Power Systems Firmware
9.6
CVE-2026-16687
Power System Buffer Overflow
9.6
CVE-2026-16835
Power System Improper Certificate Validation
8.8
CVE-2026-18821
Power System Out-of-bounds Write
8.8
CVE-2026-17414
Power System Improper Input Validation
8.4
CVE-2026-17091
Power System Integer Overflow