Medium severity · published Oct 9, 2026
CVE-2026-101022
Grid Protection Alliance openPDC and openHistorian Server-Side Request Forgery (SSRF)
4.3
CVSS
0.2%
EPSS
No
On KEV
Description
A Modbus connection feature on openPDC accepts a caller-specified destination address and port with no restriction on which internal hosts may be targeted. An authenticated user can attempt connections to arbitrary internal network destinations, revealing which destinations are reachable. With repeated attempts, an attacker may be able to map the internal network.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Confidentiality
Low
Integrity
None
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 8% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
OP
openHistorian · Grid Protection Alliance
before 2.8.580; before 2.8.585 · source: vendor
OP
openPDC · Grid Protection Alliance
before 2.9.477; before 2.9.482 · source: vendor
OD
openPDC (Docker image) · Grid Protection Alliance
before 2.9.477; before 2.9.482 · source: vendor
In the news
VulnerabilityCritical
Grid Protection Alliance openPDC and openHistorian
View CSAF
Summary
The following versions of Grid Protection Alliance openPDC and openHistorian are affected:
openPDC <2.9.477, <2.9.482 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022)
openPDC (Docker image) <2.9.477, <2.9.482 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022, CVE-2026-105278)
openHistorian <2.8.580, <2.8.585 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022)
CVSS
Vendor
Equipment
v3 9.8
Grid Protection Alliance
openPDC
5 Vulnerabilities
Deserialization of Untrusted Data, Missing Authentication for Critical Function, Server-Side Request Forgery (SSRF), Use of Hard-coded Credentials, Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
Background
Critical Infrastructure Sectors: Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-100730
A service console interface on openPDC and openHistorian deserializes a client-supplied data structure. On systems using Windows Authentication, an attacker must already be authenticated to reach this function; on systems without Windows Authentication, this is reachable by an unauthenticated network attacker. This allows an attacker to trigger deserialization of an arbitrary object graph, which coul...
Oct 8, 2026·CISA Advisories
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2026-101022
CVE.org
https://www.cve.org/CVERecord?id=CVE-2026-101022
www.cisa.gov
https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-02
github.com
https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-02.json
More from openHistorian
9.8
CVE-2026-100730
Grid Protection Alliance openPDC and openHistorian Deserialization of Untrusted Data
8.8
CVE-2026-104629
Grid Protection Alliance openPDC and openHistorian Use of Externally-Controlled Input to Select Classes or Code
7.5
CVE-2026-105281
Grid Protection Alliance openPDC and openHistorian Missing Authentication for Critical Function
5.3
CVE-2026-85479
Grid Protection Alliance openPDC and openHistorian Missing Authentication for Critical Function