High severity · published Mar 2, 2026
CVE-2025-58402
Insecure Direct Object Reference Message ID
7.5
CVSS
0.2%
EPSS
No
On KEV
Description
The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
None
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 13% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
CC
CGM CLININET · CGM
before 2025.MS4 · source: vendor
CL
Clininet · Cgm
before 2025.ms4 · source: NVD
Affected product
CC
CGM CLININET
CGM
More from CGM CLININET
9.4
CVE-2025-30050
Remote Code Execution in CGM CLININET
9.4
CVE-2025-30047
Remote Code Execution via Java Deserialization in CGM CLININET
9.4
CVE-2025-30044
RCE on uhcapache user permissions
9.3
CVE-2025-30054
Local Privilege Escalation in CGM CLININET
9.0
CVE-2025-30046
Remote Code Execution in CGM CLININET