High severity · published Aug 12, 2025
CVE-2025-40759
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6),…
7.8
CVSS
0.2%
EPSS
No
On KEV
Description
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 8% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SS
SIMATIC S7-PLCSIM V17 · Siemens
0 · source: vendor
SS
SIMATIC STEP 7 V17 · Siemens
before V17 Update 9 · source: vendor
SS
SIMATIC STEP 7 V18 · Siemens
before V18 Update 6 · source: vendor
SS
SIMATIC STEP 7 V19 · Siemens
before V19 Update 4 · source: vendor
SS
SIMATIC STEP 7 V20 · Siemens
before V20 Update 4 · source: vendor
SW
SIMATIC WinCC V17 · Siemens
before V17 Update 9 · source: vendor
SW
SIMATIC WinCC V18 · Siemens
before V18 Update 6 · source: vendor
SW
SIMATIC WinCC V19 · Siemens
before V19 Update 4 · source: vendor
SW
SIMATIC WinCC V20 · Siemens
before V20 Update 4 · source: vendor
SE
SIMOCODE ES V17 · Siemens
0 · source: vendor
SE
SIMOCODE ES V18 · Siemens
0 · source: vendor
SE
SIMOCODE ES V19 · Siemens
0 · source: vendor
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2025-40759
CVE.org
https://www.cve.org/CVERecord?id=CVE-2025-40759
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-493396.html
More from SIMATIC S7-PLCSIM V17
8.2
CVE-2024-54678
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC…
7.8
CVE-2024-49849
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety…
7.3
CVE-2024-52051
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC…