High severity · published Mar 25, 2025
CVE-2025-2717
A vulnerability, which was classified as critical, has been found in D-Link DIR-823X 240126/240802
7.2
CVSS
4.6%
EPSS
No
On KEV
Description
A vulnerability, which was classified as critical, has been found in D-Link DIR-823X 240126/240802. This issue affects the function sub_41710C of the file /goform/diag_nslookup of the component HTTP POST Request Handler. The manipulation of the argument target_addr leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)4.6% · higher than 92% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
DF
Dir-823x Firmware · Dlink
240126; 240802 · source: NVD
Affected product
DF
Dir-823x Firmware
Dlink
More from Dir-823x Firmware
7.2
CVE-2025-29635
D-Link DIR-823X Command Injection Vulnerability
9.8
CVE-2026-1125
D-Link DIR-823X set_wifidog_settings sub_412E7C command injection
9.8
CVE-2025-10123
A vulnerability was determined in D-Link DIR-823X up to 250416
9.8
CVE-2025-29043
An issue in dlink DIR 832x 240802 allows a remote attacker to execute arbitrary code via the function 0x417234
9.8
CVE-2025-29042
An issue in dlink DIR 832x 240802 allows a remote attacker to execute arbitrary code via the macaddr key value to the function 0x42232c