Medium severity · published Oct 25, 2024
CVE-2024-47801
Sharp and Toshiba Tec MFPs improperly process query parameters in HTTP requests, resulting in a reflected cross-site scripting vulnerability
6.1
CVSS
0.4%
EPSS
No
On KEV
Description
Sharp and Toshiba Tec MFPs improperly process query parameters in HTTP requests, resulting in a reflected cross-site scripting vulnerability.
Accessing a crafted URL which points to an affected product may cause malicious script executed on the web browser.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)0.4% · higher than 30% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
BF
Bp-30c25 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-30c25t Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-30c25y Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-30c25z Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c26 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c31 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c36 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c45 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c55 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-50c65 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-55c26 Firmware · Sharp
All versions, or not specified · source: NVD
BF
Bp-60c31 Firmware · Sharp
All versions, or not specified · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2024-47801
CVE.org
https://www.cve.org/CVERecord?id=CVE-2024-47801
Vendor Advisory
https://global.sharp/products/copier/info/info_security_2024-10.html
Third Party Advisory
https://jvn.jp/en/vu/JVNVU95063136/
Vendor Advisory
https://www.toshibatec.com/information/20241025_01.html
More from Bp-30c25 Firmware
9.8
CVE-2024-47406
Sharp and Toshiba Tec MFPs improperly process HTTP authentication requests, resulting in an authentication bypass vulnerability
8.1
CVE-2024-47005
Sharp and Toshiba Tec MFPs provide configuration related APIs
7.5
CVE-2024-45829
Sharp and Toshiba Tec MFPs provide the web page to download data, where query parameters in HTTP requests are improperly processed and resulting in an Out-of-bounds Read…
7.5
CVE-2024-43424
Sharp and Toshiba Tec MFPs improperly process HTTP request headers, resulting in an Out-of-bounds Read vulnerability
7.5
CVE-2024-42420
Sharp and Toshiba Tec MFPs contain multiple Out-of-bounds Read vulnerabilities, due to improper processing of keyword search input and improper processing of SOAP messages
