Critical severity · published Mar 15, 2024
CVE-2023-7017
No description published yet
9.8
CVSS
0.3%
EPSS
No
On KEV
Description
Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.3% · higher than 22% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
KL
Kontrol Lux · Sciener
6.5.x through 6.5.07 · source: vendor
KL
Kontrol Lux Firmware · Sciener
6.5.x through 6.5.07 · source: CISA