Critical severity · published Oct 10, 2023
CVE-2023-35796
A vulnerability has been identified in SINEMA Server V14 (All versions)
9.0
CVSS
0.6%
EPSS
No
On KEV
Description
A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
Required
Confidentiality
High
Integrity
High
Availability
High
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)0.6% · higher than 50% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SS
Sinema Server · Siemens
14.0 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2023-35796
CVE.org
https://www.cve.org/CVERecord?id=CVE-2023-35796
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf
More from Sinema Server
9.0
CVE-2021-40438
mod_proxy SSRF
9.9
CVE-2019-10940
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1)
9.8
CVE-2021-39275
ap_escape_quotes() may write beyond the end of a buffer when given malicious input
8.1
CVE-2020-25237
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1 Update 1), SINEMA Server (All versions < V14.0 SP2 Update 2)
7.8
CVE-2016-6486
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors