High severity · published Nov 12, 2024
CVE-2023-32736
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety…
7.3
CVSS
0.2%
EPSS
No
On KEV
Description
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
Required
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.2% · higher than 12% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SS
SIMATIC S7-PLCSIM V16 · Siemens
0 · source: vendor
SS
SIMATIC S7-PLCSIM V17 · Siemens
0 · source: vendor
SS
SIMATIC STEP 7 Safety V16 · Siemens
0 · source: vendor
SS
SIMATIC STEP 7 Safety V17 · Siemens
before V17 Update 8 · source: vendor
SS
SIMATIC STEP 7 Safety V18 · Siemens
before V18 Update 5 · source: vendor
SS
SIMATIC STEP 7 V16 · Siemens
0 · source: vendor
SS
SIMATIC STEP 7 V17 · Siemens
before V17 Update 8 · source: vendor
SS
SIMATIC STEP 7 V18 · Siemens
before V18 Update 5 · source: vendor
SW
SIMATIC WinCC Unified V16 · Siemens
0 · source: vendor
SW
SIMATIC WinCC Unified V17 · Siemens
before V17 Update 8 · source: vendor
SW
SIMATIC WinCC Unified V18 · Siemens
before V18 SP5 · source: vendor
SW
SIMATIC WinCC V16 · Siemens
0 · source: vendor
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2023-32736
CVE.org
https://www.cve.org/CVERecord?id=CVE-2023-32736
cert-portal.siemens.com
https://cert-portal.siemens.com/productcert/html/ssa-871035.html
More from SIMATIC S7-PLCSIM V16
7.8
CVE-2024-49849
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety…