High severity · published Mar 15, 2021
CVE-2021-25667
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3…
8.8
CVSS
1%
EPSS
No
On KEV
Description
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
CVSS vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)1.0% · higher than 61% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
RR
Ruggedcom Rm1224 Firmware · Siemens
4.3 before 6.4 · source: NVD
SM
Scalance M-800 Firmware · Siemens
4.3 before 6.4 · source: NVD
SS
Scalance S615 Firmware · Siemens
4.3 before 6.4 · source: NVD
SS
Scalance Sc622-2c Firmware · Siemens
through 2.0; 2.1 before 2.1.3 · source: NVD
SS
Scalance Sc632-2c Firmware · Siemens
through 2.0; 2.1 before 2.1.3 · source: NVD
SS
Scalance Sc636-2c Firmware · Siemens
through 2.0; 2.1 before 2.1.3 · source: NVD
SS
Scalance Sc642-2c Firmware · Siemens
through 2.0; 2.1 before 2.1.3 · source: NVD
SS
Scalance Sc646-2c Firmware · Siemens
through 2.0; 2.1 before 2.1.3 · source: NVD
SX
Scalance X300wg Firmware · Siemens
before 4.1 · source: NVD
SX
Scalance Xb-200 Firmware · Siemens
before 4.1 · source: NVD
SX
Scalance Xc-200 Firmware · Siemens
before 4.1 · source: NVD
SX
Scalance Xf-200ba Firmware · Siemens
before 4.1 · source: NVD
Affected product
RR
Ruggedcom Rm1224 Firmware
Siemens
More from Ruggedcom Rm1224 Firmware
9.8
CVE-2017-14491
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response
8.6
CVE-2022-31766
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions <…
7.5
CVE-2020-28400
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition
7.5
CVE-2021-25676
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3)
7.5
CVE-2019-13946
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC…