Medium severity · published Mar 25, 2019
CVE-2019-6538
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D,…
6.5
CVSS
0.9%
EPSS
No
On KEV
Description
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
CVSS vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
None
Integrity
High
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.9% · higher than 59% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
AC
Amplia Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
C2
Carelink 2090 Firmware · Medtronic
All versions, or not specified · source: NVD
CM
Carelink Monitor Firmware · Medtronic
2490c · source: NVD
CC
Claria Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
CC
Compia Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
CC
Concerto Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
CI
Concerto II Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
CC
Consulta Crt-d Firmware · Medtronic
All versions, or not specified · source: NVD
EI
Evera Icd Firmware · Medtronic
All versions, or not specified · source: NVD
MI
Maximo II Crt-d And Lcd Firmware · Medtronic
All versions, or not specified · source: NVD
MI
Mirro Icd Firmware · Medtronic
All versions, or not specified · source: NVD
MM
Mycarelink Monitor Firmware · Medtronic
24950; 24952 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2019-6538
CVE.org
https://www.cve.org/CVERecord?id=CVE-2019-6538
Third Party Advisory
http://www.securityfocus.com/bid/107544
Mitigation
https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01
More from Amplia Crt-d Firmware
6.5
CVE-2019-6540
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D,…