Medium severity · published Apr 2, 2020
CVE-2019-19000
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response
6.5
CVSS
1.1%
EPSS
No
On KEV
Description
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)1.1% · higher than 65% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
ES
Esoms · Hitachienergy
4.0 through 6.0.3 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2019-19000
CVE.org
https://www.cve.org/CVERecord?id=CVE-2019-19000
Vendor Advisory
https://search.abb.com/library/Download.aspx?DocumentID=9AKK107492A9964&LanguageCode=en&DocumentPartId=&Action=Launch
More from Esoms
9.8
CVE-2018-14805
ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file…
7.6
CVE-2019-19094
Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database
7.5
CVE-2021-35527
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by…
7.5
CVE-2021-26845
Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered
7.5
CVE-2019-19097
ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers