High severity · published Oct 28, 2019
CVE-2019-14927
An issue was discovered on Mitsubishi Electric Europe B.V
7.5
CVSS
40.9%
EPSS
No
On KEV
Description
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
None
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)40.9% · higher than 99% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
MF
Me-rtu Firmware · Inea
through 3.0 · source: NVD
SF
Smartrtu Firmware · Mitsubishielectric
through 2.02 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2019-14927
CVE.org
https://www.cve.org/CVERecord?id=CVE-2019-14927
Third Party Advisory
https://www.mogozobo.com/
Exploit
https://www.mogozobo.com/?p=3593
More from Me-rtu Firmware
9.8
CVE-2023-35762
Versions of INEA ME RTU firmware 3.36b and prior are vulnerable to operating system (OS) command injection, which could allow remote code execution
9.8
CVE-2023-29155
Versions of INEA ME RTU firmware 3.36b and prior do not require authentication to the "root" account on the host system of the device
9.8
CVE-2023-2131
Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code
9.8
CVE-2019-14931
An issue was discovered on Mitsubishi Electric Europe B.V
9.8
CVE-2019-14930
An issue was discovered on Mitsubishi Electric Europe B.V