Medium severity · published Feb 11, 2020
CVE-2019-13924
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All…
5.4
CVSS
0.8%
EPSS
No
On KEV
Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
Low
Integrity
Low
Availability
None
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)0.8% · higher than 57% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SX
Scalance X-200irt Firmware · Siemens
All versions, or not specified · source: NVD
SX
Scalance X-300 Firmware · Siemens
before 4.1.3 · source: NVD
SX
Scalance Xb-200 Firmware · Siemens
before 5.2.4 · source: NVD
SX
Scalance Xc-200 Firmware · Siemens
before 5.2.4 · source: NVD
SX
Scalance Xf-200 Firmware · Siemens
before 5.2.4 · source: NVD
SX
Scalance Xp-200 Firmware · Siemens
before 5.2.4 · source: NVD
SX
Scalance Xr-300 Firmware · Siemens
before 4.1.3 · source: NVD
SX
Scalance Xr-300wg Firmware · Siemens
before 4.1.3 · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2019-13924
CVE.org
https://www.cve.org/CVERecord?id=CVE-2019-13924
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf
www.us-cert.gov
https://www.us-cert.gov/ics/advisories/icsa-20-042-07
More from Scalance X-200irt Firmware
8.6
CVE-2019-10942
A vulnerability has been identified in SCALANCE X-200 switch family (incl
7.5
CVE-2019-19301
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO,…
7.5
CVE-2019-13946
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC…
7.5
CVE-2019-10923
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation
5.5
CVE-2019-6567
A vulnerability has been identified in SCALANCE X-200 switch family (incl