High severity · published Dec 13, 2018
CVE-2018-13814
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP…
8.8
CVSS
1.7%
EPSS
No
On KEV
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)1.7% · higher than 77% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SH
Simatic Hmi Comfort Outdoor Panels Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Comfort Panels Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Ktp Mobile Panels Ktp400f Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Ktp Mobile Panels Ktp700 Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Ktp Mobile Panels Ktp700f Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Ktp Mobile Panels Ktp900 Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi Ktp Mobile Panels Ktp900f Firmware · Siemens
before 14.0 · source: NVD
SH
Simatic Hmi MP Firmware · Siemens
All versions, or not specified · source: NVD
SH
Simatic Hmi OP Firmware · Siemens
All versions, or not specified · source: NVD
SH
Simatic Hmi TP Firmware · Siemens
All versions, or not specified · source: NVD
SW
Simatic Wincc (tia Portal) · Siemens
before 14.0 · source: NVD
SW
Simatic Wincc Runtime · Siemens
before 14.0; before 14.0 · source: NVD
Affected product
SH
Simatic Hmi Comfort Outdoor Panels Firmware
Siemens
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2018-13814
CVE.org
https://www.cve.org/CVERecord?id=CVE-2018-13814
Third Party Advisory
http://www.securityfocus.com/bid/105931
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf
More from Simatic Hmi Comfort Outdoor Panels Firmware
9.1
CVE-2019-6572
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1…
8.1
CVE-2018-13813
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update…
7.5
CVE-2019-6575
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl
7.5
CVE-2019-6568
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition
7.5
CVE-2018-13812