High severity · published Sep 12, 2018
CVE-2018-13807
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions)
8.6
CVSS
4.2%
EPSS
No
On KEV
Description
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.
CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
None
Integrity
None
Availability
High
Scope
Changed
Exploitation
Is it being used?
Exploit prediction (EPSS)4.2% · higher than 91% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SX
Scalance X300 Firmware · Siemens
before 4.0.0 · source: NVD
SX
Scalance X408 Firmware · Siemens
before 4.0.0 · source: NVD
SX
Scalance X414 Firmware · Siemens
All versions, or not specified · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2018-13807
CVE.org
https://www.cve.org/CVERecord?id=CVE-2018-13807
Third Party Advisory
http://www.securityfocus.com/bid/105331
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-447396.pdf
Third Party Advisory
https://ics-cert.us-cert.gov/advisories/ICSA-18-254-05
More from Scalance X300 Firmware
9.8
CVE-2021-29998
An issue was discovered in Wind River VxWorks before 6.5
8.8
CVE-2018-4833
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl
6.5
CVE-2017-2681
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product
6.5
CVE-2017-2680
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2)
6.1
CVE-2018-4848
A vulnerability has been identified in SCALANCE X-200 switch family (incl