High severity · published Jul 3, 2018
CVE-2018-10596
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates
7.1
CVSS
1.3%
EPSS
No
On KEV
Description
Medtronic 2090 CareLink Programmer
uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.
CVSS vector
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
Attack vector
Network
Complexity
High
Privileges
Low
User interaction
Required
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)1.3% · higher than 71% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
2C
2090 Carelink Programmer Firmware · Medtronic
All versions, or not specified · source: NVD
Affected product
2C
2090 Carelink Programmer Firmware
Medtronic
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2018-10596
CVE.org
https://www.cve.org/CVERecord?id=CVE-2018-10596
global.medtronic.com
https://global.medtronic.com/xg-en/product-security/security-bulletins/carelink-2090-29901.html
www.cisa.gov
https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-058-01
Third Party Advisory
https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-01
More from 2090 Carelink Programmer Firmware
4.9
CVE-2018-5446
Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format
4.8
CVE-2018-5448
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system