Critical severity · published Aug 5, 2017
CVE-2017-9860
An issue was discovered in SMA Solar Technology products
9.8
CVSS
2.2%
EPSS
No
On KEV
Description
An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the inverter is compromised completely. This allows the attacker to do nearly anything: for example, giving access to the local OS, creating a botnet, using the inverters as a stepping stone into companies, etc. NOTE: the vendor reports that this attack has always been blocked by "a final integrity and compatibility check." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Confidentiality
High
Integrity
High
Availability
High
Scope
Unchanged
Exploitation
Is it being used?
Exploit prediction (EPSS)2.2% · higher than 83% of CVEs
Exploited in the wildNo evidence yet
CISA KEVNot listed
Ransomware campaign useNot known
Affected products
Which versions
SB
Sunny Boy 1.5 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 2.5 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 3.0 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 3.6 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 3000tl Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 3600 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 3600tl Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 4.0 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 4000tl Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 5.0 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 5000 Firmware · Sma
All versions, or not specified · source: NVD
SB
Sunny Boy 5000tl Firmware · Sma
All versions, or not specified · source: NVD
References
NVD
https://nvd.nist.gov/vuln/detail/CVE-2017-9860
CVE.org
https://www.cve.org/CVERecord?id=CVE-2017-9860
www.sma.de
http://www.sma.de/en/statement-on-cyber-security.html
www.sma.de
http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf
Third Party Advisory
https://horusscenario.com/CVE-information/
More from Sunny Boy 1.5 Firmware
9.8
CVE-2017-9861
An issue was discovered in SMA Solar Technology products
9.8
CVE-2017-9859
An issue was discovered in SMA Solar Technology products
9.8
CVE-2017-9855
An issue was discovered in SMA Solar Technology products
9.8
CVE-2017-9854
An issue was discovered in SMA Solar Technology products
9.8
CVE-2017-9853
An issue was discovered in SMA Solar Technology products