HomeIntelligenceBrief
VULNERABILITY BRIEF 🔴 Critical Vulnerability

Critical Remote Code Execution Vulnerabilities (CVE‑2024‑42384 – CVE‑2026‑62654) in Siemens Reyrolle 7SR5 Industrial Control System

Siemens Reyrolle 7SR5 controllers running firmware older than V2.70 contain fourteen critical flaws that enable remote code execution and denial‑of‑service. Energy operators must patch immediately to maintain audit‑ready vulnerability‑management controls.

Verisq™ Intelligence · 📅 September 15, 2026 · 📰 cisa.gov
🔴
Severity
Critical
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
Actions
4 recommended
📰
Source
cisa.gov

Critical Remote Code Execution Vulnerabilities (CVE‑2024‑42384 – CVE‑2026‑62654) in Siemens Reyrolle 7SR5 Industrial Control System

What It Is – Siemens Reyrolle 7SR5 firmware versions prior to V2.70 contain a suite of fourteen high‑severity flaws (integer overflows, authentication bypass, out‑of‑bounds writes, missing integrity checks, etc.) that enable remote code execution, denial‑of‑service, and unauthorized configuration changes.

Exploitability – CVSS v3.1 9.8 (Critical). Public advisories indicate that the vulnerabilities are exploitable over the network; proof‑of‑concept exploits have been published for several CVEs.

Affected Products – Siemens Reyrolle 7SR5 (all releases < V2.70) deployed in energy‑sector control networks worldwide.

Why It Matters for Trust & Control Assurance

  • Vulnerability Management – Demonstrates the need for continuous monitoring of firmware versions and rapid patch deployment to satisfy the control objective of “maintain a documented, auditable patch‑management process.”
  • Evidence of Due Diligence – Maintaining verifiable records of patch status provides defensible audit evidence across frameworks (e.g., NIST CSF 2.0, ISO 27001).
  • Operational Continuity – Unpatched control‑system firmware can be leveraged to disrupt critical energy services, directly impacting the trust that regulators and customers place in the operator’s security posture.

Recommended Actions

  1. Inventory all Reyrolle 7SR5 devices and verify current firmware version.
  2. Apply Siemens‑provided update to version 2.70 or later immediately.
  3. Validate the update with functional testing and integrity checks.
  4. Record patch‑deployment dates, device IDs, and verification results in a centralized CMDB for audit readiness.
  5. Integrate automated firmware‑version scanning into your continuous control monitoring platform.

Source: CISA Advisory – ICSA‑26‑258‑05

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-05

This Verisq Intelligence Brief is an independent analysis. Read the original reporting at the link above.

Vulnerability exposure

Is this CVE in your supply chain?

Verisq matches published vulnerabilities against the software your vendors run, so you know which relationships this touches before the next review.

See vendor exposure →